YPIL, Cable Accessories, Heat Shrink, Heat Shrinkable, Cold Shrinkables Cable Termination,  Non tracking Tubing
Yamuna-Power
Yamuna-Power
YPIL, Heat Shrinkable, Telecom Cable Joints Yamuna-Power Power Cable Jointing Kits Yamuna-Power Cable Jointing Accessories Yamuna-Power Electrical Projects Yamuna-Power Enquiry for Cable Joints,Terminations,Accessories Yamuna-Power Opportunities for Entrepreneurship Yamuna-Power Contact for Cable Jointing Systems Yamuna-Power Newsletter Yamuna-Power Sitemap Yamunapower  
Yamuna-Power
Yamuna-Power
Yamuna-Power
  Joints
  Terminations
  Accessories
    End Caps
    Medium Wall Tubing
    Heat Shrinkable Anti Tracking Tubing
    Medium voltage Insulation Tape
    Cable Repair Sleeve
    Cable Breakout Boots
    Breakout Boots/Shapes
  FRP / Composite
  VCB
  Composite Polymer Insulators
  Elbow Connectors
  SCIT

Medium Voltage Insulation Tape

DENSONS HEAT SHRINKABLE MEDIUM VOLTAGE INSULATION TAPE
Anti-Track adhesive coated Heat Shrink Tape specially designed for insulation & protecting medium voltage bus bar upto 36 kV

Features
Reduces bus bar clearance requirements
Protects against accidental flashover
Halogen free
Shrink Temperature : 120o  C
Anti-track
Continuous operation temperature: -25o  C to 130o  C
Medium Voltage Insulation Tape,Heat Shrink Medium Voltage Insulation Tape
 
Medium Voltage Insulation Tape,Heat Shrink Medium Voltage Insulation Tape
 

Dimensions

Availabale in width of 25 mm & 50 mm
TOP

Technical Data

Properties Requirements Testing Method

Medium Voltage Bus Bar Tap
e

For Service upto 36 kV over bolted Bus Bar

ORDERING
REF. Number

ROLL WIDTH (min.)

BACKING THICKNESS RECOVERED (Nom)

ROLL LENGTH

Installation Instruction
A 2/3 overlap is recommended
One  layer application required up to 17 kV
Two  layer application required up to 25 kV
Three  layer application required up to 36 kV

Clearance with Insulation

For Service upto 36 kV over bolted Bus Bar

SYSTEM VOLTAGE

BIL
kV

p to p
(mm)

p to g
(mm)

P to p : phase to Phase orientation Spacing based on metal to metal.
p to g : Phase to ground orientation dimensions prior to insulation.
Space based on insulation wall thickness per application range of above tables.